Report


Request for Unsupported Devices

Here, you can report detailed information on a device that does not work with IONA to request support. As this page uses WebHID API to obtain device information, you need to visit this page with Google Chrome or Chromium based browsers that enables WebHID support. Obtained information is only about the product itself, and does not contain any privacy information such as PC environment specific parameters, serial numbers, or something about you. These information might not be enough to support the device. In such case, author may ask additional information to support the device. We don’t ensure that all reported devices will be supported though we try. It may take a long time, or we may give up to support some devices if it’s difficult.

Known Issues, or Unresolved Reports

This site contains unresolved reported issues. If there is already a request for the device, please wait until the issue is resolved. It’s good to add some comments in the thread to encourage us to prioritize the issue, or you can get a notification when the issue is fixed.

How to Report

Please connect the device under the issue to the PC. You need to know the device name that appears on the PC. Please push the connect button below. You will see a dialog as follows. This dialog should contain the device name in the list. You need to choose the one you want to report, then press connect button.

Prompt

Once the device is connected correctly, device information appears in the controller information section below. Please copy all the information, then report it to author’s Twitter account. DM is open for everyone.



Controller Information





Adavanced Report

As information that can be obtained via Chrome is really relimited, we cannot get enough hints to support the device. If information obtained above wasn’t enough, and you are happy to help me, please follow this step to gather information via IONA-US itself.

Step 1; Flash debug firmware for the investigation

We use a dedicated firmware that gather detailed USB transaction logs. You need to understand following risks.

Connect IONA-US to your PC by following the instruction at [Firmware Update)(firmware_en) page. You should not connect anything to the IONA’s P2 USB port at this point.

   
Write 0% 100%
Verify 0% 100%

Result



Step 2: Logging target device information

If everything went well, you will see the LED is blinking. Once you ensure the LED blinking, connect your target device to the IONA’s P2 USB port. You may see the LED is turned OFF if the all logging buffer is fullfilled. Even if it’s still blinking, we may have enough logging data. So, never mind.

It will be finished immediately, and you can go to the next step now. Press ‘SERVICE’ button here. It will make the LED turned off. This indicates the log data is stored to the persistent area, and the device is ready to upload the data to your PC. You can obtain the log at the next step.

Step 3: Obtain the log

Press the button below, and you will see the device selection dialog. Please choose the device you chose at the first step.

   
Read 0% 100%

Result